Error Codes
The BJC-2100 does not beep or have any LEDs to indicate errors. All errors are reported via the computer with error messages.
Error Condition | Error Indication on Computer | Error Code | Possible Solution |
Paper Feed | The Printer is out of paper | | Add Paper |
Paper Jam | A paper jam has occurred | | Remove any paper jammed |
Cover is open | The printer's front cover is open | | Close the front panel |
No cartridge | BJ Cartridge error occured | | Install the BJ cartridge properly and close the printers front cover. |
Head Mismatch | An incorrect cartridge was installed in the printer. | | Insure the scanner IS cartridge is installed when scanning or the BJ Cartridge is installed when printing |
EEPROM | An error that possibly requires a service call has occurred | 6800 | Try unplugging the printer for 30 seconds, if not requires a service. |
Home Position | An error that possibly requires a service call has occurred | 5000 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |
Carriage Error | An error that possibly requires a service call has occurred | 5100 | Try unplugging the printer for 30 seconds, if not requires a service. |
Temperature Sensor | An error that possibly requires a service call has occurred | 5400 | Try unplugging the printer for 30 seconds, if not requires a service. |
No Cartridge Error | An error that possibly requires a service call has occurred | 5600 | Try reinstalling Cartridge or replacing the cartridge |
Waste Full | An error that possibly requires a service call has occurred | None | Needs Service |
Cleaning Error | An error that possibly requires a service call has occurred | 5C00 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |
Scanner IS-22 | An error that possibly requires a service call has occurred | 5210 | |
Waste Error Reset
1: Remove the Cartridge
2: Unplug the AC Power Cord
3: Close Front access panel
3: Hold down the RESUME/RESET button and plug in the AC power cord
4: Release RESUME/RESET after plugging in the AC Power cord.
5: Press the RESUME/RESET once within 5 seconds and release the RESUME/RESET .
6: Press and HOLD RESUME/RESET for two seconds or more and release it.
7: Press and HOLD RESUME/RESET for two seconds or more and release it.
8: Unplug AC Power Cord to set data.
|