Canon BJC-2100 Printer

Error Codes

The BJC-2100 does not beep or have any LEDs to indicate errors. All errors are reported via the computer with error messages.

Error ConditionError Indication
on Computer
Error
Code
Possible Solution
Paper FeedThe Printer is out of paper Add Paper
Paper JamA paper jam has occurred Remove any paper jammed
Cover is openThe printer's front cover is open Close the front panel
No cartridgeBJ Cartridge error occured Install the BJ cartridge properly and close the printers front cover.
Head MismatchAn incorrect cartridge was installed in the printer. Insure the scanner IS cartridge is installed when scanning or the BJ Cartridge is installed when printing
EEPROMAn error that possibly requires a service call has occurred6800Try unplugging the printer for 30 seconds, if not requires a service.
Home PositionAn error that possibly requires a service call has occurred5000Make sure no obstructions are blocking the cartridge movement, if not needs service.
Carriage ErrorAn error that possibly requires a service call has occurred5100Try unplugging the printer for 30 seconds, if not requires a service.
Temperature SensorAn error that possibly requires a service call has occurred5400Try unplugging the printer for 30 seconds, if not requires a service.
No Cartridge ErrorAn error that possibly requires a service call has occurred5600Try reinstalling Cartridge or replacing the cartridge
Waste FullAn error that possibly requires a service call has occurredNoneNeeds Service
Cleaning ErrorAn error that possibly requires a service call has occurred5C00Make sure no obstructions are blocking the cartridge movement, if not needs service.
Scanner IS-22An error that possibly requires a service call has occurred5210 

Waste Error Reset

1: Remove the Cartridge
2: Unplug the AC Power Cord
3: Close Front access panel
3: Hold down the RESUME/RESET button and plug in the AC power cord
4: Release RESUME/RESET after plugging in the AC Power cord.
5: Press the RESUME/RESET once within 5 seconds and release the RESUME/RESET .
6: Press and HOLD RESUME/RESET for two seconds or more and release it.
7: Press and HOLD RESUME/RESET for two seconds or more and release it.
8: Unplug AC Power Cord to set data.