General
Cartridge
- BC-02 - Black Ink & Integral Print Head
- BC-05 - Colour Ink & Integral Print Head
- BC-06 - Photo Ink & Integral Print Head
- BC-09f - Fluorescent Ink & Integral Print Head
Serial Number
Location - Cream coloured label on the rear of the printer, centre back of sheet feed.
Error Codes
The BJC-1000 does not beep or have any LEDs to indicate errors. All errors are reported via the computer with error messages.
| Error Condition | Error Indication on Computer | Error Code | Possible Solution |
| Paper Feed | The Printer is out of paper | | Add Paper |
| Paper Jam | A paper jam has occurred | | Remove any paper jammed |
| Home Position | An error that possibly requires a service call has occurred | 5000 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |
| Carriage Control | An error that possibly requires a service call has occurred | 5100 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |
| Temperature Sensor | An error that possibly requires a service call has occurred | 5400 | Try unplugging the printer for 30 seconds, if not requires a service. |
| No Cartridge Error | An error that possibly requires a service call has occurred | 5600 | Try reinstalling Cartridge or replacing the cartridge |
| Cleaning Error | An error that possibly requires a service call has occurred | 5C00 | Make sure no obstructions are blocking the cartridge movement, if not needs service. |
| EEPROM | An error that possibly requires a service call has occurred | 6800 | Try unplugging the printer for 30 seconds, if not requires a service. |
| Waste Full | An error that possibly requires a service call has occurred | None | Needs Service |
Waste Error Reset
1: Remove Cartridge
2: Unplug the AC Power Cord
3: Hold down the RESUME button
4: Release RESUME after plugging in the AC Power cord.
5: Press the RESUME once within 5 seconds and release the RESUME .
6: Press and HOLD RESUME for two seconds or more and release it.
7: Press and HOLD RESUME for two seconds or more and release it.
8: Unplug AC Power Cord to set data.
|