Apricot Cyberworks GuideThis guide is designed as a quick reference for basic operation of the Cyberworks software and does not contain information on all aspects of the software. The Cyberworks software supplied with an Apricot Computer is specifically designed to work with the Dataflex PC Comms Office 14.4 modem and may not work with other manufacturers modem hardware. Getting StartedConnecting the modem to the telephone socketThe Dataflex modem is approved for connection to direct exchange lines of the PSTN (Public Switched Telephone Network), but not share lines, “one plus one” carrier systems or some PBX (Private Branch Exchange). The modem has a REN (Ring Equivalence Number) of 1 and when connected to the phone line with other phone equipment the total REN for the line must not exceed the Lines REN capacity, your local Phone line supplier will be able to check and advise you on the total REN capacity of your line. Turning on an Online machine for the first timeWhen you first power on the Online PC and run through the installation of Windows 95, you will eventually get the displayed message : "select the connect button from Control Panel Printers applet to connect CyberWorks print driver to fax port" OKClick on the OK button, this message is a Windows 3.x message and is nothing to worry abut. To load CyberWorks, double click on the CyberWorks icon on the desktop. Fax FunctionsTo utilise fax functions, CyberWorks must be loaded. To load CyberWorks, double click on the CyberWorks Icon on the desktop. To receive a fax:Let the modem answer the incoming call, or click receive on the Program Screen. If the voice option is set (see Settings), the selected greeting will start to play, and it will then detect that a fax is being sent and automatically switch into fax mode and receive the fax. To view the fax see Message Centre. To cancel an incoming fax, click abort on the Program Screen. To send a fax:You can send a fax from any Windows application by selecting the CYBERP printer under the print option of the application you are in, or setting the CYBERP printer to be your default printer (see Windows Help files/Manual). This will launch the CyberWorks Phone Book. Select a previously configured recipient or create a new one, select the cover page you wish to send and select the send fax icon. To check the status of a fax see Message Centre. To cancel an outgoing fax, click abort on the Program Screen (this will leave it in the Message Centre for automatic re-faxing, see Message Centre and Settings). Voice FunctionsTo utilise voice functions, CyberWorks must be loaded. To load CyberWorks, double click on the CyberWorks Icon on the desktop. To receive voice mail:Let the modem answer the incoming call. The selected greeting wll play and a message can be left by the caller. To play back the message, see Message Centre. To record a Voice mail message:Two methods are available:
The Message CenterTo load the message center, press the Message Center icon on the CyberWorks program screen. Messages received displayThis area of the display allows you to view and playback any faxes or voice mail you have received, as well as displaying status of faxes sent. Symbols are used by CyberWorks to help identify the type of message in the display. The symbols covered in this guide are listed below.
The status of each item in the display is also shown. A brief description of each is listed below:
To view a fax or to play a voice mail, double click on the required item. Once viewed/played the symbol will disappear. To re-send a failed fax, highlight the fax and click the Re-send fax icon. To print a fax, highlight the fax and click the print fax icon. The Phone CenterCyberWorks has the ability to convert your modem into a "hands-free" speaker phone. Make sure the modem and sound card are cabled as per Modem Connections. Configure:When you first load CyberWorks, it automatically configures the modem. If you experience problems or change phone lines, then the following procedure should be adopted. Load the phone center by clicking on the phone center icon on the CyberWorks program screen. Click on the Configure button. Then click on the Train button. CyberWorks will now automatically reconfigure the modem. Answering incoming calls using Phone Centre: To answer incoming calls, simply click on the hand set. After completion of the call, click on the hang-up button. Making outgoing calls using Phone Centre: To call out, simply dial the desired number (either by entering the numbers on the keyboard or using the mouse on the Phone Center keypad) then click the Dial button (or press enter if using the keyboard). Modem ConnectionsAs default, the modem is not connected to the sound system of the computer. To enable full multimedia capability, follow the diagram below. SettingsThere are currently two default settings for the Dataflex modem. Option 1. The onboard serial ports are set as COM1 (Address 3F8h - IRQ 4) and COM2 (Address 2F8h - IRQ 3) in the system BIOS, the modem is set to COM3 (Address 3E8h - IRQ 4) Option 2. The onboard serial ports are set as COM1 (Address 3F8h - IRQ 4) and COM3 (Address 3E8h - IRQ 4) in the system BIOS, the modem is set to COM2 (Address 2F8h - IRQ 3) To find the Settings for your Modem do the following:
The default settings for the modem in the Windows 95 System Properties are as detailed below,
The CyberWorks settings (which are accessible by clicking Configure on the Message Center and selecting Settings) are detailed in the pictures below: Troubleshooting / DiagnosticsFollowing is a checklist of things that should be done prior to calling for technical assistance.
Windows 95 DiagnosticsTo run the Windows 95 diagnostics, CyberWorks must first be unloaded. To find the Settings for your Modem do the following:
Check that the responses do not indicate any errors. CyberWorks DiagnosticsTo run the CyberWorks diagnostics, CyberWorks must first be unloaded. Under the CyberWorks program group, run the Modem Information program. The following screen will appear... Click on Interrogate to start the diagnostics. Check that none of the results in the Modem Responses box contain any errors. To restore the factory default settings to the modem, click on Restore. Microsoft FaxIf you are using Microsoft Fax rather than Cyberworks, you may get problems with it initialising the modem properly. This has been found to be a problem with the Microsoft Preinstall software, the following procedure overcomes the problem -
General FAQCyberworks Not ConnectingSet the actual modem speed in the Communications Centre Settings to 7200. This will be a halfway mark for the two machines to negotiate to. As you may be aware of Cyberworks decided to trash the International Standard of Falling Back ie 19200 down to 2400, instead goes upwards 2400 to 19200 so that the time it takes to do so they miss each other. Not a good fix, but one that works. Apricot are looking into it. Using Handset to Record Greeting MessageRecording using a handset doesn't work on a Dataflex Modem, the function may be there in Cyberworks, but will not work on the Dataflex Modem.......Nuff Said. External recording the Customer has to, when they dial in enter in their record code, which will be more than likely 4321 as this is the default and it will tell them to record there message and when it says press the pound sign to end the recording session this actually means #. Will not work from Mercury connections. Phone BookThis "feature" does not work from the Phone Centre on Cyberworks. From the Phone Centre you can click on the Phone Book button to enable you to select a number from the phone book, this does not work. However, it does work when you want to send a Fax. Apricot have confirmed this as a "known!" problem, according to the information that they have from Dataflex. HP DJ400 PrinterIf you get cyberworks printing a dark grey background on one of these printers then its the Windows driver and the way it communicates with cyberworks. Installing the HP320 driver should solve the problem but leave the HP400 driver there for normal printing.
|